The direction limit switch US has the features of a safety switch with forced actuation. It has three switching positions with stay-put feature and therefore retains the last position. The switch is preferably used as robust floor switch and signals the position of the car to the floor. The limit switch is actuated at the roller lever by change-over cams.
norms | EN 81-20, EN 81-50, EN 60947-5-1 |
switching capacity | Ui = 500 V Ith = 10 A Uimp = 4 kV AC-15: Ue = 230 V Ie = 6 A DC-13: Ue = 200 V Ie = 0.3 A |
short-circuit capacity | T10 A F 16 A |
contact material | fine silver |
actuation- / return force | 0.65 N (stay-put) |
connection | by slot nut max. 2.5 mm², cable entry 2x M20x1.5 |
level of protection | IP40 |
ambient air temperature | -30 °C up to +80 °C |
installation position | any |
weight | 820 g |
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checbox-analytics | 11 Months | This cookie is used to store the user's consent for cookies of the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 Months | This cookie is used to store the user's consent for cookies of the category "Necessary". |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
other | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other". |
Pll_language | 6 Months | This cookie is used to set the language of the website. |
viewed_cookie_policy | 11 months | This cookie is used to check whether the user has consented to the use of cookies or not. It does not store any personal data. |