DL(F)1-WV

Standard device (IP54) for vertical installation

For vertical installation we offer the door interlock DL(F)1 also in level of protection IP54 as special version DL(F)1-WV. To ensure the water protection, the DL(F)1W is equipped with a sealed metal cover and a hard chrome-plated latch bolt for better corrosion protection.

DLF1-WV-L-X15-CHR(u) .10S

DLF1-WV-L-X15-CHR(u) .10S

Dimensions DLF1-WV-R-X20-CHR(u) .10S

Features

general:

  • metal housing with high stability
  • silent due to buffers in both directions
  • maintenance-free by permanent lubrication with high quality lubricants (up to -30 °C)
  • oiled felt ring at latch bolt for lubrication as well as for sealing against dirt and dust (at X-dimension 10 mm)
  • constrained faulty closure at DLF1-WV for use in passenger lifts
  • contacts with solid fine silver plating for a reliable function even at low voltages and currents
  • auxiliary switch as normally closed contact and/or normally open contact
    with two galvanically isolated
  • contacts possible
  • extensive range of accessories

special features:

  • waterprotection (IP54) at vertical installation position in the door frame (-WV)
  • metal cover with rubber seal instead of transparent cover
  • chromed latch bolt for better oxidation protection
  • terminal block with all electrical connections
  • connection for bowden cable or cable pull for actuation or unlocking available, e.g.
    application 1:unlocking from the pit ladder (< 1.80 m according to EN 81-20)
    application 2:offset emergency release triangle (< 2 m according to EN 81-20)
    application 3:actuation by bowden cable as alternative to pull rod

Order information codes

Technical data

norms EN 81-20, EN 81-50, EN 81-21, EN 60947-5-1
certificates type approval certificate:
EU-DL 013 (DLF1-WV) and EU-DL 015 (DL1-WV)
UK-DL 013 (DLF1-WV) and UK-DL 015 (DL1-WV)
switching capacity:
switch for locking mechanism
monitoring switch
auxiliary switch .9/…
auxiliary switch .90/01
Ui = 250 V Ith = 10 A Uimp = 4 kV
AC-15: Ue = 230 V Ie = 2 A DC-13: Ue = 200 V Ie = 2 A
AC-15: Ue = 230 V Ie = 2 A DC-13: Ue = 200 V Ie = 0.5 A
AC-15: Ue = 230 V Ie = 2 A DC-13: Ue = 200 V le = 0.5 A
AC: Ue = 250 V Ie = 6 A EN 61058
DC: Ue = 200 V Ie = 0.25 (0.1) A
DC: Ue = 60 V Ie = 1.0 (0.5) A
DC: Ue = 24 V Ie = 3.0 (2.0) A
short-circuit capacity T 10 A F 16 A
contact material fine silver
actuation:
actuation torque (typical)
actuation force (typical)
max. force in non-operating state
1.7 Nm at the roller lever
45 N at the pull rod 20 N at the roller lever (at 35 mm stroke)
5 N at the pull rod
connection by screw terminal max. 2.5 mm²
cable entry M25 with reducing ring and cable gland M20x1.5
level of protection IP54, vertical customary position and cable gland above
ambient air temperature -10 °C up to +65 °C (special version up to -30 °C)
weight 850 g to 1100 g (according to version)

Downloads

Catalogue

Operating instructions

Declaration of conformity
DE / EN

Declaration of conformity
DE / FR

Declaration of conformity
DE / IT

Declaration of conformity
DE / ES

Declaration of conformity
DE / CZ

Declaration of conformity
EN

Type examination certificate
EU-DL-013-DLF1-WV

Type examination certificate
EU-DL-015-DL1-WV

UK-Type examination certificate
UK-DL-013-DLF1-WV

Type examination certificate
UK-DL-015-DL1-WV